Améliorer la fiabilité électromécanique grâce à l’ASE
Figure 1. Common motor faults (CF=Center frequency, RS = Running speed, LF=Line frequency) Electrical signature analysis (ESA) is a predictive maintenance (PM) technology that uses the motor’s supply voltage and operating current to identify existing and developing faults throughout the motor system. These measurements act as transducers, and [...]
Défaut de barre de rotor Problème de maintenance : Alerte au capteur de vibrations
A 398 kW MV motor powering a fan in a cement plant exhibited unusual behavior. Vibration monitoring equipment indicated vibration amplitudes that became chronic over time. The maintenance team, unaware of the problem, ran the motor until the bearings needed replacing. This occurred repeatedly, with no remedy [...]
Analyse de la signature du courant du moteur à courant continu
Introduction Evaluation of a 10 HP, 1.0 SF, Ins F, 1750 RPM, 240 V, 33 amp armature, 240 V, 1.23 amp field DC electric motor, from the DC drive output. A DC drive fault and poor brush condition were reported. Discussion When testing a DC electric motor with the ALL-TEST [...]
Éliminer le déséquilibre de tension
Voltage imbalance degrades the performance and reduces the lifespan of a three-phase motor. A voltage imbalance across the motor terminals can cause a current imbalance far exceeding the voltage imbalance. Unbalanced currents lead to torque pulsations, increased vibration and mechanical stress, increased losses resulting in reduced efficiency [...]
Détection des défauts de l’entraînement du moteur à modulation de largeur d’impulsion à l’aide de l’analyse de la signature électrique
L’industrie utilise de plus en plus de variateurs de vitesse pour les moteurs à courant alternatif et le variateur à modulation de largeur d’impulsion (PWM) est devenu la norme industrielle commune pour les applications de faible à moyenne puissance. Comme les autres composants du système moteur, le [...]
Analyse des circuits de moteur pour améliorer l’énergie, la fiabilité et les coûts de production
Introduction Les informations faisant état de pannes d’électricité dues à l’augmentation de la demande, les méthodes de contrôle des coûts énergétiques ne sont plus une option verte, mais plutôt une stratégie de survie. Dans l’industrie, le principal potentiel de maîtrise de l’énergie réside dans les stratégies énergétiques des [...]
Surveillance des machines et comment la technologie ESA peut améliorer la fiabilité de votre usine
By: William Kruger, ALL-TEST Pro Over 300 million electric motors are used in infrastructure, large buildings, and industry worldwide. These motors account for approximately two-thirds of industrial energy consumption. Electricity is needed in almost every sector of a factory to provide the motive power that operates the equipment [...]
Réduire les coûts grâce aux technologies ESA et MCA™
Rotating Equipment Management Over 300 million electric motors are used in infrastructure, large buildings, and industry worldwide. These motors account for approximately two-thirds of industrial energy consumption. Electricity is required in nearly every area of a factory to provide the motive power that operates the equipment producing the [...]
Comment tester complètement les moteurs à induction triphasés à l’aide d’un test de moteur hors tension ?
Les gens effectuent souvent des tests d’inductance du moteur avec des méthodes qui ne permettent pas d’évaluer avec précision l’ensemble de la situation. Des tests inadéquats peuvent conduire à un remplacement prématuré des équipements, à de mauvaises analyses de coûts et à d’autres résultats négatifs. Les tests [...]
Défaillance du palier du moteur du VFD : Défaut du moteur ou problème du variateur ?
Les améliorations apportées à la technologie des entraînements à fréquence variable (EFV) ont permis de réduire les coûts, d’améliorer la fiabilité et, surtout, d’accroître l’utilisation. La plupart des systèmes modernes d’entraînement à fréquence variable sont dotés de diagnostics internes qui permettent un arrêt automatique en cas de [...]
Essais de réception des moteurs
Les essais de réception des moteurs constituent un élément essentiel de nombreux programmes de maintenance préventive et permettent de détecter les problèmes électriques avant qu’ils n’entraînent des temps d’arrêt considérables. Avec plus de 35 ans d’expérience en matière de tests de moteurs, ALL TEST PRO® a déterminé [...]
Amélioration de la fiabilité électrique par la mise en œuvre d’une analyse du circuit du moteur
Lorsque vous souhaitez déterminer l’état de santé de votre moteur, l’analyse des circuits du moteur (MCA™) est un choix privilégié dans tous les secteurs d’activité. Cette méthode de test des moteurs hors tension vous permet d’évaluer l’état de santé de votre moteur, transformateur, générateur et autres équipements [...]